  • Reasons for excessive humidity in the cold aisle of the computer room

    Reasons for excessive humidity in the cold aisle of the computer room

    When relative humidity climbs too high (typically above 60-70% RH), moisture in the air can condense on cooler surfaces inside servers and network equipment. This condensation can form on circuit boards, connectors, and metal components. Relative Humidity (RH) is a percentage that shows the amount of water vapor in the air compared to the maximum amount it could hold at that specific temperature. This is a critical metric because the. If you're worried about your PC or data center operating at the right temperature, you're on the right track: The combination of ambient temperature and relative humidity (RH) directly affects reliability hardware performance and lifespan. In this article, we'll delve into the world of humidity and explore how it can wreak havoc on your trusty computer. Both extremes compromise reliability, uptime, and long-term data center performance.

    [PDF Version]
  • What type of UPS power supply should be used for network server racks

    What type of UPS power supply should be used for network server racks

    The size and weight of a UPS is primarily dependent on power requirements. Data center UPSs often look like standard 42U racks because of the enormous loads they're expected to support, while traditional network closets and server rooms typically only need one or two 2U rack-mounted UPS. The type. Protecting servers, network gear, and storage in a rack requires a dependable uninterruptible power supply (UPS). They are available in various sizes and capacities, ranging from 1U to 4U in height and 500VA to 10kVA.


  • How to test grounding in a network server rack

    How to test grounding in a network server rack

    Use a ground impedance tester or micro-ohm meter to test the quality of earth ground connection at the chassis. Hardwiring (Direct Ground Connection) Hardwiring involves establishing a direct connection between the server rack and the facility's grounding electrode. Let's examine why server rack grounding matters, the key techniques used in the industry, and how to implement an effective grounding strategy. Should you ground your server rack? Absolutely. The main purpose of grounding data racks is to secure people from the harmful influence of electric circuits and prevent. For optimal performance, knowing how to ground your server rack is essential to ensure the safety and reliability of your IT equipment.


  • How to calculate the network patch cord calculation for server racks

    How to calculate the network patch cord calculation for server racks

    In such cases, you'll need to calculate the cable length based on the total inches required for the path. Uses industry-standard formulas with proper service loops and buffer allowances. Explore our signal flow canvas, rack builder, and studio layout tools. Click and drag to navigate, scroll to zoom. You. There is no special tool that I've found for figuring out the length you need. Cable category Cat5e U/UTP Cat6 U/UTP Cat6A F/UTP Cat7 S/FTP Cat8 S/FTP. Multiply that across dozens of ports and you end up with the classic spaghetti rack: hard to read, hard to change, and surprisingly easy to break during routine re-dressing. Whether you're installing Cat6 cables in your home or deploying fiber optic cable in a commercial space, using a cable length calculator ensures that you purchase just the right amount of cable.

    [PDF Version]
  • How long should the fiber optic cable be left when entering the server rack

    How long should the fiber optic cable be left when entering the server rack

    A service loop is a small extra length of cable left intentionally during installation. It may look unnecessary at first glance. Note that fiber optic cable and coaxial cable will typically follow similar rules for excess cable. What is a service loop in wiring? Service loops are excess cable (slack) that is designed to be in addition to any cable needed for the actual planned drop (run) length and terminations. Excess. CABLExpress recently released its new "Fiber Optic Cabling Best Practices Guide," a set of guidelines "recommended pre-, post-, and during installation" of the company's Skinny-Trunk cabling products in accordance with the TIA-942 data center standard and based on its own field experience.